23
The oscillator, in this WayCool® unit, is operated by a 4 RPM gear motor (WC-OSCGEARMTR)
that delivers 50 in/lbs. in torque. As the gear motor rotates, the blower duct
(WC-LGBLOWERDUCT) oscillates in a 110-degree arc, which cools an area of approximately
9500 square feet.
* The design of the oscillator requires the blower duct to sit loosely on top of the unit.
• Do not place hands in blower duct (WC-LGBLOWERDUCT) while unit is operational!
• Do not attempt to stop blower duct (WC-LGBLOWERDUCT) from oscillating!
5
4
2
UNIT DOES NOT OSCILLATE
1. Ensure that the unit is plugged into a standard 120-Volt outlet.
2. Ensure that the oscillator switch is in the ON position.
3. Ensure that the gear motor is running. To do this, shut off the whole unit by turning the
main switch to the OFF position and leave the rocker switch for the gear motor in the ON
position. You should then be able to hear the gear motor.
4. If the motor is running:
• The blower duct may be fastened too tight against the top of the WayCool®. The nut
above the brace should be loosened allowing 1/16” clearance between the bottom of
the blower duct and the top of the WayCool®.
• If the blower duct is not too tight, the linkage may be damaged. Look for visible
damage to the linkage rod or the lever. If any of the linkage parts are damaged, they
will need to be replaced.
5. If the motor is not running, the motor may have failed or there could be a wiring problem.
contact a certified electrician. If the motor is determined to have failed, it must be replaced.